Brand Name : BAIKONG

Certification : IEC,GB

Place of Origin : Sichuan,China

MOQ : 1set(MOQ)

Price : $1000-$100000/set

Payment Terms : L/C, Western Union, T/T

Supply Ability : 300 sets/sets per week

Delivery Time : 15Days OR To be negotiated

Packaging Details : Standard wooden boxes for outer packing/To be negotiated

Product Name : IP55 Dual Power Fire Pump Automatic Inspection Cabinet

Color : Non-standard Custom

Size : customizable

Series : Fire Pump Controllers

Inspection Cycle : 1-168 Hours

Application : Fire Extinguishing System

Inspection Circuitidity : 1-14 circuit (special requirements)

Rated Voltage : 380V

QA : 1year

Maximum : 15-220KW

Contact Now

IP55 Dual Power Fire Pump Automatic Inspection Cabinet

Product Overview

With the rapid development of urbanization, there are more and more types of buildings with different conditions, large core application of combustible materials in buildings and other factors that may be vulnerable to fire, plus people's low awareness of fire prevention, which greatly increases the possibility of fire. Although at present each building department is equipped with fire extinguishing system, but experience and lessons have proved that the success of fire fighting depends mainly on whether the fire water supply equipment is intact. Fire pump is an important part of water skyfire system, its characteristic is usually not for a long time, once the use is 100%, due to idle for a long time, plus the pump room environment humidity, it is easy to happen fire pump shaft and impeller corrosion, rust and the phenomenon of the electrical components cannot be used properly, that there is a fire, the fire pump will not operate properly, Unable to extinguish the fire, endangering the safety of people's lives and property.

In order to solve the fire problem, our company combined with the above problems, independent research and development out of the set alarm, monitoring, control and management in the integration of digital intelligent fire inspection cabinet, and has set up a batch production and use: this product can prevent fire pump corrosion, be affected with damp be affected with damp, water pump is abnormal, the function of fault, do "find one thousand days, with soldiers" purpose. The product conforms to the technical specifications of national fire pressurized water supply equipment standard GB 27898.3-2011, and has passed the inspection and certification of National Fire Engineering technology Research Center.

Functional Table

Inspection Cabinet Function Way Inspection Cabinet Function Way

Automatic Inspection Can Be

Set At Any Time Cycle

BYO

The Main Circuit Switch Elements

Can Be No Greater Than 2s For Patrol Inspection

Customization

Inspection At Low Speed,

Low Frequency And No Pressure

BYO

Pipeline Network Protection Function,

Patrol Inspection With Pressure

Customization

In Case Of Fire Signal,

The Inspection Is Immediately

Put Into Operation

BYO Intelligent Alarm Function Customization
Acoustic And Optical Alarm Function BYO

With 485 Communication Function,

The Firefighting System Network

Customization
Failure Storage Recording Function BYO

Pool Liquid Level And Pipeline Water

Pressure Alarm Function

Customization

Over-Pressure, Overcurrent, Short-Circuit,

Phase Deficiency And Other

Protection Functions

BYO

Pool Liquid Level And Pipeline Water

Pressure Alarm Function

Customization

Model Meaning

ZY ¨/¨ ¨ XJF
Fire Inspection Actual Power Rated Pressure, Rated Flow Rate Fire-Fighting Pressurized Water Supply Equipment

Parameter

  • Rated voltage:0-380V.
  • rated current: AC A.
  • Inspection Power: Single Pump
  • Maximum:15-220KW.
  • Inspection circuit: 1-14 circuit (special requirements).
  • Inspection cycle: 1-168 hours, single pump inspection time: 10-300S (inspection cycle and time can be set according to need).

Operating Environment

  • Environmental temperature: -10℃ ~ + 40℃.
  • Ambient humidity: 0~90% ℃ and no dew.
  • Elevation: less than 2,000 meters.


Product Tags:

Fire Pump IP55 Integrated Distribution Cabinet

      

Fire Pump Inspection Integrated Distribution Cabinet

      

IP55 Fire Pump Electrical Distribution Cabinet

      
Quality IP55 Dual Power Integrated Distribution Cabinet For Fire Pump Inspection for sale

IP55 Dual Power Integrated Distribution Cabinet For Fire Pump Inspection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sichuan Baikong Electric Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0